Case Report

Accidental Journeys: Intrauterine Contraceptive Device Migration to The Sigmoid Colon And Right Ovary – A Report of Two Cases

Abstract

Ectopic migration of intrauterine contraceptive devices (IUCDs) to neighboring organs is infrequent, but can lead to severe consequences. This article presents two cases of IUCD migration resulting in serious outcomes, including sigmoid colon penetration in the first case (a 25-year-old) and right ovary penetration and contraceptive failure leading to pregnancy in the second case (a 19-year- old). The IUCD was inserted 6 months ago and 2 years ago in the first and second cases, respectively. Both cases underwent surgical exploration and IUCD removal. Fortunately, both patients experienced uneventful recoveries without any complications. In conclusion, although uncommon, IUCD ectopic migration may result in contraceptive failure and, in some cases, organ perforation. Thorough evaluation during care visits is necessary for proper IUCD placement, and radiological assessment should be performed in cases of a ‘missed IUCD,’ even if the patient is asymptomatic. Timely removal of an ectopic IUCD is strongly advised to minimize potential risks.

1. Rowlands S, Oloto E, Horwell DH. Intrauterine devices and risk of uterine perforation: current perspectives. Open Ac- cess J Contracept. 2016;7:19-32. PMID: 29386934; PMCID: PMC5683155.https://doi.org/10.2147/OAJC.S85546
2. Cheung ML, Rezai S, Jackman JM, Patel ND, Bernaba BZ, Hakimian O, et al. Retained Intrauterine Device (IUD): Triple Case Report and Review of the Literature. Case Rep Obstet Gynecol. 2018;2018:9362962. PMID: 30627466; PMCID: PMC6304543.https://doi.org/10.1155/2018/9362962
3. Aminu M, Dattijo L, Adamu M. Ovarian penetration by copper intrauterine device: A rare phenomenon. Saudi J Med Med Sci. 2018;7(3):183-5.https://doi.org/10.4103/sjhs.sjhs_62_18
4. Mederos R, Humaran L, Minervini D. Surgical removal of an in- trauterine device perforating the sigmoid colon: a case report. Int J Surg. 2008 Dec;6(6):e60-2. PMID: 17409036.https://doi. org/10.1016/j.ijsu.2007.02.006
5. Takahashi H, Puttler KM, Hong C, Ayzengart AL. Sigmoid co- lon penetration by an intrauterine device: a case report and literature review. Mil Med. 2014 Jan;179(1):e127-9. PMID: 24402999.https://doi.org/10.7205/MILMED-D-13-00268
6. Heinemann K, Reed S, Moehner S, Minh TD. Risk of uterine perforation with levonorgestrel-releasing and copper intra- uterine devices in the European Active Surveillance Study on Intrauterine Devices. Contraception. 2015 Apr;91(4):274- 9. PMID: 25601352.https://doi.org/10.1016/j.contracep- tion.2015.01.007
7. Almatary A, Alsharif A, Ghabisha S, Ahmed F, Badheeb M. Open surgical retrieval of intra-uterine contraceptive device perforating the ileum: A case report. Int J Surg Case Rep. 2023 Aug;109:108635. PMID: 37552923; PMCID: PMC10425888. https://doi.org/10.1016/j.ijscr.2023.108635
8. Goldstuck ND, Wildemeersch D. Role of uterine forces in in- trauterine device embedment, perforation, and expulsion. Int J Womens Health. 2014;6:735-44. PMID: 25143756; PMCID: PMC4132253.https://doi.org/10.2147/IJWH.S63167
9. Atileh LIA, Mourad MA, Haj-Yasin D, Shlash L, Kaylani LZ, Fadila N. Intrauterine Contraceptive Device Perforating the Cecum, a Pregnancy Complication? Gynecol Minim Invasive Ther. 2019 Apr-Jun;8(2):83-5. PMID: 31143630; PMCID: PMC6515750. https://doi.org/10.4103/GMIT.GMIT_109_18
10. Boortz HE, Margolis DJ, Ragavendra N, Patel MK, Kadell BM. Migration of intrauterine devices: radiologic findings and implications for patient care. Radiographics. 2012 Mar- Apr;32(2):335-52. PMID: 22411936.https://doi.org/10.1148/ rg.322115068
11. Alharbi KY, Filimban HA, Bafageeh SW, Binaqeel AS, Bayzid MA, Brasha NM. Removal of a Migrated Intrauterine Contra- ceptive Device Perforating the Terminal Ileum: A Case Report. Cureus. 2022 Sep;14(9):e29748. PMID: 36340548; PMCID: PMC9621717.https://doi.org/10.7759/cureus.29748
12. Rahnemai-Azar AA, Apfel T, Naghshizadian R, Cosgrove JM, Farkas DT. Laparoscopic removal of migrated intrauterine de- vice embedded in intestine. JSLS. 2014 Jul-Sep;18(3). PMID: 25419105; PMCID: PMC4236077.https://doi.org/10.4293/ JSLS.2014.00122
13. Gill RS, Mok D, Hudson M, Shi X, Birch DW, Karmali S. Lap- aroscopic removal of an intra-abdominal intrauterine device: case and systematic review. Contraception. 2012 Jan;85(1):15- 8. PMID: 22067801.https://doi.org/10.1016/j.contracep- tion.2011.04.015
Files
IssueVol 8 No 6 (2023): November-December QRcode
SectionCase Report(s)
DOI https://doi.org/10.18502/crcp.v8i6.16235
Keywords
Case Report Intrauterine Contraceptive Device Ectopic migration Sigmoid colon Adnexal organs

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.
Al-wageeh S, Ahmed F, Alyhari Q, Altam A. Accidental Journeys: Intrauterine Contraceptive Device Migration to The Sigmoid Colon And Right Ovary – A Report of Two Cases. CRCP. 2024;8(6):258-263.