Percutaneous Endovascular Retrieval of an Embolized Chemotherapy Port-A-Cath Fragment from the Superior Vena Cava Utilizing a Snare System: A Case Report
Abstract
Port catheters are recommended for patients requiring long-term intravenous therapy, particularly in cancer patients who are debilitated and require administration of chemotherapy or cytotoxic drugs. Mechanical complications of port placement include port occlusion, displacement, and catheter fracture. In this case report, we present the endovascular retrieval of a fractured chemotherapy port catheter fragment from the superior vena cava using a snare device. A 60-year-old woman with metastatic breast cancer presented with infusion difficulty through her 18-monthold subclavian chemotherapy port. The surgeon noticed that the port had not been fully extracted, prompting an urgent consultation for intervention. Fluoroscopyguided retrieval of an SVC catheter fragment was achieved via femoral access using an Amplatz snare after failed EN Snare attempts. The patient was discharged postprocedure without complications. Proactive chemotherapy port surveillance enables early complication management. Catheter fractures necessitate multidisciplinary care,
where endovascular snare retrieval augmented by surgical excision demonstrates optimal safety and efficacy.
[2] Diamantidis D, Papatheodorou N, Perente S, Botaitis S, Diamantidis Sr DE, Papatheodorou Sr N, et al. Asymptomatic
spontaneous migration of the tip of Port-a-Cath system into the right internal jugular vein: a case report of an uncommon complication. Cureus. 2022;14(7). https://doi.org/10.7759/cureus.26937
[3] Smouse HB, Fox PF, Brady TM, Swischuk JL, Castañeda F, Pham MT, editors. Intravascular foreign body removal.
Semin Intervent Radiol. 2000;17(2):179-90. https://doi.org/10.1055/s-2000-9445
[4] Ribeiro FS, Kumakura H, da Silva ES, Puech-Leão P, De Luccia N. Removal of intravascular foreign bodies with a simple low-cost method: a report of 5 cases. J Endovasc Ther. 2021;28(3):474-80. https://doi.org/10.1177/15266028211007470
[5] Ghaderian M, Sabri MR, Ahmadi AR. Percutaneous retrieval of an intracardiac central venous port fragment using snare with triple loops. J Res Med Sci. 2015;20(1):97-9.
[6] Choksy P, Zaidi SS, Kapoor D. Removal of intracardiac fractured port-A catheter utilizing an existing forearm peripheral intravenous access site in the cath lab. J Invasive Cardiol. 2014;26(2):75-6.
[7] Bonitto S, Yadav B, Vellody R, Meagher E. Catheter fragment removal from a persistent left superior vena cava in a pediatric patient. Pediatr Radiol. 2023;53(6):1207-10. https://doi.org/10.1007/s00247-023-05599-5
[8] Sudhakar B, Teja BR. Successful recovery of central venous catheter fragment from coronary venous sinus and right
ventricle: a case report. Radiol Case Rep. 2021;16(8):2261-5. https://doi.org/10.1016/j.radcr.2021.03.064
[9] Kalyoncuoğlu M, Öztürk S, Durmuş G, Sarı M, Can MM. Percutaneous Removal of a Broken and Embolized Transvenous Chemotherapy Port Catheter in the Left Pulmonary Artery by Using a Snare-loop Catheter. Haseki Tip Bulteni. 2017;55(1):70. https://doi.org/10.4274/haseki.3321
| Files | ||
| Issue | Vol 11 No 1 (2026): January-February | |
| Section | Case Report(s) | |
| DOI | https://doi.org/10.18502/crcp.v11i1.22169 | |
| Keywords | ||
| Port catheter Chemotherapy Snare device | ||
| Rights and permissions | |
|
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. |

