Case Report

Extreme Electrical Storm in Acute Inferior ST‑Elevation Myocardial Infarction Successfully Terminated by Dual Sequential Defibrillation: A Case Report

Abstract

Electrical storm and refractory ventricular fibrillation (VF) are rare but catastrophic complications of acute myocardial infarction (AMI) and are associated with high mortality despite adherence to advanced cardiac life support protocols. We report a 48‑year‑old man with a history of ischemic heart disease, percutaneous coronary intervention, and hypertension who presented with severe exertion‑induced chest pain and was diagnosed with acute inferior ST‑elevation myocardial infarction. During monitoring, he developed recurrent malignant ventricular arrhythmias progressing to refractory VF despite repeated biphasic defibrillation and antiarrhythmic therapy. Sequential defibrillation with 200‑J shocks was performed with procedural sedation and analgesia before each attempt, with a cumulative delivered energy of approximately 4000 J. Intravenous amiodarone, lidocaine, and magnesium sulfate were administered, and thrombolytic therapy with reteplase was initiated. Persistent VF ultimately required dual sequential defibrillation, which successfully restored a stable sinus rhythm. The patient was transferred for urgent coronary angiography and was discharged three days later in stable clinical condition. This case highlights the potential role of dual sequential defibrillation as a rescue strategy in refractory ventricular fibrillation complicating acute myocardial infarction.

[1] Kudenchuk PJ, Brown SP, Daya M, Rea T, Nichol G, Morrison LJ, et al. Double Sequential External Defibrillation and Vector‑Change Defibrillation for Refractory Ventricular Fibrillation. N Engl J Med. 2022;387(25):2347‑2356. doi:10.1056/NEJMoa2211483
[2] Cheskes S, Verbeek PR, Drennan IR, McLeod S, Turner L, Pinto R, et al. Defibrillation strategies for refractory ventricular fibrillation: contemporary evidence and clinical implications. Resuscitation. 2023;186:109771. https://doi.org/10.1016/j.resuscitation.2023.109771
[3] Panchal AR, Bartos JA, Cabañas JG, Donnino MW, Drennan IR, Hirsch KG, et al. Advanced Cardiac Life Support:
2024 Focused Update on Resuscitation Science. Circulation. 2024;149(5):e277‑e288. https://doi.org/10.1161/CIR.0000000000001209
[4] Cabañas JG, Myers JB, Williams JG, De Maio VJ, Bachman MW, Kline JA, et al. Dual sequential defibrillation in refractory ventricular fibrillation: systematic review and meta‑analysis. Resuscitation. 2023;188:109826. https://doi.org/10.1016/j.resuscitation.2023.109826
[5] Perkins GD, Gravestock I, Lott C, Greif R, Monsieurs K, Olasveengen T, et al. European Resuscitation Council Guidelines for Resuscitation 2024: Updates in management of ventricular arrhythmias. Resuscitation. 2024;203:110367.
https://doi.org/10.1016/j.resuscitation.2024.110367
Files
IssueVol 11 No 2 (2026): March-April QRcode
SectionCase Report(s)
Keywords
Electrical storm Inferior ST‑elevation Myocardial infarction Dual sequential defibrillation

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.
Mirbagheri S, Hajizadeh Ahmari K. Extreme Electrical Storm in Acute Inferior ST‑Elevation Myocardial Infarction Successfully Terminated by Dual Sequential Defibrillation: A Case Report. CRCP. 2026;11(2):82-85.